KEIM EPS insulation panels meet all the requirements for using KEIM ETIC systems. Reliable adherence regarding the required properties is ensured through a contractual agreement and regular monitoring of the production facilities.
Facade insulation using KEIM EPS insulation panels is particularly interesting from the point of view of rapid amortisation of the planned insulation measures.
ETIC Systems with EPS insulation panels are hardly inflammable when the corresponding fire protection measures are put in place.

OVERVIEW OF KEIM EPS INSULATION PANELS

KEIM EPS-grau 032/034 WDV

Insulation panels made of expanded polystyrene rigid foam according to DIN EN 13163, CFC-free, flame-retardant B1 in accordance with DIN 4102, dimensionally accurate, shrinkage-free and quality-monitored, for improved thermal insulation.

The panels comply with the quality guidelines for EPS rigid foam fa?de insulation panels for ETICS of the IVH (Industrieverband Hartschaum e.V. = Industrial Association for Rigid Foam) and of the Fachverband f?r WDVS e.V. (Trade Association for ETICS).

Colour shade
Grey


Rated value of thermal conductivity: 0.032 W/mK

Panel size 100 x 50 cm
Blunt, Panel thickness 20 - 400 mm

Stepped profile*
Panel thickness 30 - 400 mm

Tongue and groove*
Panel thickness 40 - 400 mm

* on request

Packaging

panel thickness mm

m² per bunch

20 12.0
30 8.0
40 6.0
50 4.5
60 4.0
70-80 3.0
90 2.5
100-120 2.0
130-160 1.5
170-300 1.0
310-400 0.5

Füllschaum FM 110 (illbruck, foam filler)

Moisture-curing, one-component, CFC-free polyurethane foam. After curing flame-retardant according to building material class B1 DIN 4102, WLG (thermal conductivity) 040. KEIM Füllschaum has excellent insulation properties and is used to foam-fill joints between installed EPS and MW panels. General building authority test certificate P-NDS 4-312.

Packaging
750 ml can

Spray gun
Required to apply the foam filler

 

KEIM Bossenplatten EPS 035 WDV

Insulation panels made of expanded polystyrene hard foam according to DIN EN 13163, CFC-free, flame-retardant B1 according to DIN 4102, accurate to dimension and free of shrinkage, quality-monitored. With central trapezoidal groove.

Groove type I: 30 mm outside , 20 mm inside, 15 mm deep

Groove type II: 35 mm outside, 20 mm inside, 15 mm deep

Packaging

panel thickness mm m² per pack
60 4,0
70-80 3,0
90 2,5
100-120 2,0
130-160 1,5
170-200 1,0

KEIM Bossenkelle
Special trowel for reinforcing the groove, with 2 trapezoidal wedg
Spare wedge type I
Spare wedge type II

Packaging
1 piece


KEIM Bossengewebeprofile (Boss mesh profiles)
Prefabricated glass fibre mesh profiles to reinforce the trapezoidal groove.

Mesh profile, surface
Length 2 m, width 20 cm
Type I F, trapezoidal groove 30 / 20 / 17
Type II F, trapezoidal groove 37 / 20 / 17


Mesh profile, outer corner
Length 10 / 10 cm
Type I A, trapezoidal groove 30 / 20 / 17
Type II A, trapezoidal groove 37 / 20 / 17

Mesh profile, inner corner
Length 9 / 9 cm
Type I i, trapezoidal groove 30 / 20 / 17
Type II i, trapezoidal groove 37 / 20 / 17


End profile mesh
Type I, trapezoidal groove 30 / 20 / 17
Type II, trapezoidal groove 37 / 20 / 17

Packaging:
10 pcs per carton

KEIM MW-Brandriegel 035 (Fire barrier)

Mineral wool panel acc. to DIN EN 13162 and DIN 4108-10, application type WAP-zg, tear resistance = 5 kPa, quality-monitored, non-flammable A1 acc. to DIN EN 13501-1, coated on both sides.

Solely approved and suitable for use as a fire barrier in ETIC systems made from EPS.

Rated value of thermal conductivity: 0.035 W/mK.

Corrugated side = adhesive side

Smooth side = reinforcement and plaster side

Packaging

panel thickness mm m² per pallet pack per pallet
100 11,52 12
120 9,60 10
140 7,68 8
160 5,76 6
180 5,76 6
200 5,76 6
220 4,80 10
240 4,80 10
260 3,84 8
280 3,84 8
300 2,88 6

Low-flammable ETIC systems with EPS insulation material

Fire stops must be made from mineral wool insulation materials to install low-flammable ETICS with EPS insulation materials. The selection of mineral wool insulation materials as well as performance and arrangement of fire stops have to comply with the information of the general building approval in connection with the current building regulations relating hereto.

You will find more information on fire protection in KEIM ETIC systems at https://www.keim.com/fileadmin/user_upload/downloads/wdvs-planungsservice/Praxismerkblatt_Brandschutz_WDVS_mit_EPS-Daemmstoffen.pdf

Approved insulation materials as fire stop:

MW-Brandriegel 035 (mineral wool fire stop) 
Mineralwolle-Lamellen 041 (mineral wool lamellae)

 

 

 

 

 

 

Low-flammable ETIC systems with EPS insulation material

SYSTEM AND COMPLEMENTING PRODUCTS
KEIM MINERAL INSULATION PANELS

Fibre-free, pure mineral insulation panels

To the product
KEIM MINERAL WOOL INSULATION PANELS

Secure insulation with incombustible insulation materials.

To the product
This site uses cookies. If you continue surfing on this site, you agree to the use of cookies.